EN 10204 inspection documents
| Type | Content | Validated by |
|---|---|---|
| 2.1 Declaration of compliance | Statement of conformity, no test results | Manufacturer |
| 2.2 Test report | Non-specific test results | Manufacturer |
| 3.1 Inspection certificate | Specific test results of the delivered product | Manufacturer's authorised inspection representative, independent of production |
| 3.2 Inspection certificate | As 3.1, additionally validated | Manufacturer's representative and purchaser's or official inspector |
Traceability
Bar and plate are identified by heat number from receipt to cutting. Where required, parts are marked with heat or lot codes, and certificates are referenced in the shipment documents.
Verification methods
- PMI (positive material identification) by XRF or OES confirms alloy composition — useful for stainless, nickel and copper alloys.
- Hardness testing (Brinell, Rockwell, Vickers per ISO 6506/6508/6507) verifies heat-treatment condition.
- Laboratory testing (chemical analysis, tensile, impact) is performed by accredited partner laboratories when specified.