MACHINING.TRPrecision Machining. Engineered in Turkey.
Micrometer measurement of a turned brass part
  1. Home
  2. Quality
  3. Dimensional Inspection

Quality

Dimensional inspection

Measurement makes tolerances real. The method must be capable of resolving the tolerance — and the result must be reported in a way that relates to your drawing.

Methods

workpiecebridge-type CMMX
FIG.01A bridge-type coordinate measuring machine probes the part in its datum reference frame.
MethodMeasuresNotes
CMMPosition, profile, form, complex geometryProgrammed against datums; reports per feature
Micrometers, calipersDiameters, lengthsFast; check calibration and technique
Bore gaugesInternal diameters, roundnessTwo-point vs. three-point affects results
Height gauge on surface plateHeights, positionsGood for simple prismatic parts
Thread gaugesThread fitGO / NO-GO per tolerance class
Roughness testerRa, Rz and moreCorrect cut-off and evaluation length
Optical / vision systemsSmall features, profilesNon-contact for small or soft parts

Measurement capability

A rule of thumb is that the measuring system's uncertainty should be small relative to the tolerance — often 10 % to 20 % of it. For tight tolerances, temperature control and gauge studies (MSA) become essential.

Reports

Reports list each characteristic with its balloon number, nominal, tolerance, measured value and result. Sampling follows the agreed plan, for example ISO 2859-1 or 100 % inspection of critical characteristics.

Micrometer measurement of a turned brass part
Micrometer measurement of a turned brass part

Enquiry

Have a drawing to review?

Send your 2D drawing and 3D model with quantities, material and required documents. An engineer reviews manufacturability, tolerances and inspection before quoting.

What to include in your enquiry